E-Rickshaw & Home Inverter Battery Sizing Guide Nepal: Exact kWh, Shift & Load Formulas
By Nexus Technical Desk · Nov 26, 2026

Buying an under-sized battery leaves e-rickshaw drivers parked at 3 PM missing peak evening fares—and leaves families sitting in the dark mid-evening. Buying a mismatched voltage fries controllers or wastes money. Here is the plainspoken sizing method our Biratnagar engineers use every day.
Quick Answer: For e-rickshaws, first match your motor controller voltage (`51.2V` for 48V systems; `61.4V` for 60V/L5 systems), then pick 105Ah–140Ah for passenger loops or 153Ah–232Ah for heavy cargo/fleet routes. For home inverters, calculate Required Storage (Wh) = (Running Watts × Hours) ÷ 0.72, then choose 12.8V (`1.28 kWh`), 25.6V (`2.56 kWh`), or 51.2V (`5.12 kWh`).
Part 1: E-Rickshaw, E-Loader & E-Scooter Selection Method
Step 1 — Never Guess Voltage (Match Your Controller)
- 48V E-Rickshaw / City Safari Controllers: Pair with 51.2V LiFePO4 packs (
TK-3W-51105orTK-3W-51140). - 60V L3 / L5 Auto & Heavy E-Loader Controllers: Pair with 61.4V LiFePO4 packs (
TK-3W-61105,TK-3W-61140,TK-3W-61153, orTK-3W-61232). - 2-Wheeler E-Scooters: Use 51.2V 45Ah (
TK-2W-5145,2.30 kWh, price upon contact) for 48V scooters or 61.4V 48Ah (TK-2W-6148,2.95 kWh, price upon contact) for 60V commuters.
Step 2 — Match Capacity (kWh) to Daily Shift Distance
| TRONTEK Model (SKU) | Energy | Indicative NPR | Best Matched Route & Vehicle |
|---|---|---|---|
51V 105Ah Complete Set (TK-3W-51105) | 5.37 kWh | रू 1,45,500 | Standard 48V city passenger e-rickshaws with midday rest/top-up |
51V 140Ah Complete Set (TK-3W-51140) | 7.17 kWh | रू 1,94,500 | Full-day city & Koshi/Terai corridor routes (IP65 sealed) |
61V 105Ah Complete Set (TK-3W-61105) | 6.45 kWh | रू 1,72,500 | 60V high-torque passenger autos and incline routes |
61V 140Ah Complete Set (TK-3W-61140) | 8.60 kWh | रू 2,27,000 | Commercial multi-shift e-autos & passenger-cargo mixes |
61V 153Ah Complete Set (TK-3W-61153) | 9.39 kWh | रू 2,75,500 | Heavy-duty all-day operators avoiding mid-day charging (-10°C to +55°C) |
61V 206Ah / 232Ah Sets (TK-3W-61206 / 61232) | 12.65–14.24 kWh | रू 3,86,000–3,95,000 | L5 passenger autos, inter-city routes & heavy cargo loaders |
Part 2: Home Inverter & Solar Battery Sizing Formula
Do not judge a home battery by Ah alone—Ah means completely different energy at 12.8V versus 25.6V or 51.2V. Always size in Watt-hours (Wh) using this exact two-step formula:
Step A: Required Battery Wh = (Running Appliance Watts × Backup Hours) ÷ 0.72
(Accounts for 85% safe LiFePO4 Depth of Discharge × ~85% inverter efficiency)
Step B: Compare Required Wh directly against kWh rating:
1,280 Wh = 1.28 kWh | 1,920 Wh = 1.92 kWh | 2,560 Wh = 2.56 kWh | 5,120 Wh = 5.12 kWh3 Worked Nepali Household Examples
- 1Flat / Parents & Children Study Setup (`~170W` for `5 hours`):
- Load: 2 LED lights (
20W) + 1 ceiling fan (70W) + Wi-Fi router (15W) + laptop/phone charging (65W) =170W. - Formula:
(170 × 5) ÷ 0.72 = 1,180 Wh. - Best Fit: GEON GE 1500 / 12.8V 100Ah (
1,280 Wh, रू 43,500) for an existing 12V inverter, GE 2500 / 12.8V 150Ah (1,920 Wh, रू 65,500) for extra runtime, or the all-in-one GEON Integrated GELITHIUM 1250 (रू 65,500).
- 1Family Home + Fridge & Work-From-Home (`~450W` for `4 hours`):
- Load: Refrigerator average draw + TV + 3 fans + lights + desktop PC =
450W. - Formula:
(450 × 4) ÷ 0.72 = 2,500 Wh. - Best Fit: GEON GE 3000 / 25.6V 100Ah (
2,560 Wh, रू 80,500) or integrated GELITHIUM 2500 (25.6V 100Ah) (रू 1,07,500).
- 1Solar Hybrid Home, Clinic or Workshop (`~900W` for `4 hours`):
- Formula:
(900 × 4) ÷ 0.72 = 5,000 Wh. - Best Fit: GEON GE 5500 / 51.2V 100Ah (
5,120 Wh, रू 1,65,500) paired with GELITHIUM Solar 5500VA (रू 1,15,500) and NB Solar 550W Panels (रू 36,000).
Need help matching your exact vehicle controller or home appliances? Message our Biratnagar engineers on +977 970-4525751 or browse all models in the Products Catalog.